Tower
Hof Tower is responsible for aerodrome and ground control at Hof-Plauen Airport. Hof-Plauen has a D(HX) CTR and published IFR procedures that do not require coordination for clearance.
SID Assignment
Endpoint | SID | Runway | Initial Climb | After Departure |
Remark |
ABERU | 1S | 08 | FL70 | Contact München Radar 129.525 |
- |
2T | 26 | ||||
KULOK |
1S | 08 | 5000 ft |
||
2T | 26 | ||||
LASGA | 1S | 08 | FL 70 |
||
2T | 26 | ||||
PEROX | 1S | 08 | |||
2T | 26 | ||||
TABAT |
1S | 08 |
|||
2T | 26 |
Operating direction
The operating direction is selected by the tower; München Radar (FRK) must always be informed of the current operating direction.
IFR departures
IFR departures are to be handed over with radar or wake turbulence separation. IFR departures on the same SID are to be handed over with 5 NM or (if higher) wake turbulence separation. Tower is responsible for the separation between 2 IFR departures and between IFR departures and IFR approaches on a missed approach procedure until the transfer of communications of all flights involved.
IFR arrivals
IFR approaches are handed over from München Radar to Hof Tower using one of the published approach procedures in compliance with radar or (if required) wake turbulence separation. München Radar is responsible for the separation, speed assignments from the tower are not permitted without coordination with München Radar.
Both runway directions are equipped with an RNP approach.
IFR visual approaches
IFR visual approaches are approved for both operating directions without further regulations. München Radar must coordinate these with Hof Tower prior to clearance.
Low Visibility Procedures
There are no defined low visibility procedures in Hof. If the minima cannot be adhered to, no flights are possible.
Use of runway
For operating direction 08, a backtrack generally required. Smaller aircraft can depart directly from intersection B.
VFR traffic
Arrivals and departures
Arrivals and departures take place via the published mandatory reporting points or can be instructed individually. There are no published holding procedures for VFR within the control zone.